R.S. Electronic Controls, Inc.


			

EDC / Submersible Pump Control Wire Isolation Systems
for
Service Stations, Truck Stops and Commercial Fueling Sites.

FAQ
Installation Manual
Compare Products
Demo Software
Testimonials
Technical
NEC Code

Electronic Device Controller

A note to our foreign visitors.

We are sorry but at this time we do not support 240 Volt control wiring.

PDF version of our color Brochure.

Our EDC is a high technology product that eliminates feedback in submersible pump control wiring, and at the same time simplifies installation, operation and the servicing of other devices that are connected to it.

What are it's Benefits?

bullet100% elimination of feedback in submersible pump control wiring.
bulletOSHA Regulations, Lockout Tagout and Safety procedures are simplified.
bulletOne dispenser can be serviced without shutting down an entire site. (with proper wiring)
bulletLower on site maintenance costs.
bulletUL and CUL LISTED, File No. E100900, Industrial Control Equipment
bulletApproved, The City of New York, Department of Buildings, Bureau of Electrical Control, Calendar #41825 

We have 12 different Models to choose from, in 2 different size enclosures.

Model 101-041600

Maximum of 16 Inputs and either 4 or 8 Outputs
Enclosure size: 12"H x 12"W x 4"D

Model 101-xxxxxx pricing

Outputs Inputs Model No. Price
4 8 101-040800 $ 640
4 16 101-041600 $ 850
8 8 101-080800 $ 740
8 16 101-081600 $ 950

Model 102-043200

Maximum of 32 Inputs and either 4 or 8 Outputs

Enclosure size: 12"H x 18"W x 4"D

Model 102-xxxxxx pricing

Outputs Inputs Model No. Price
4 8 102-040800 $ 700
4 16 102-041600 $ 900
4 24 102-042400 $ 1110
4 32 102-043200 $ 1310
8 8 102-080800 $ 800
8 16 102-081600 $ 1000
8 24 102-082400 $ 1210
8 32 102-083200 $ 1410

What size do I need?

Outputs

The number of outputs is determined by the number of submersible pumps used. If there are 3 submersibles we need 4 outputs.

Inputs

The number of inputs is determined by the number of submersible control wires used. For example, 4 - three product dispensers would require 12 inputs (4 x 3 = 12). If these 4 dispensers were blenders they would require 8 inputs (4 x 2 = 8).

Each Diesel dispenser requires only one input, even if it has a satellite dispenser connected to it.

Example

A typical station with 4 - three product dispensers, and 6 Diesel master - satellite dispensers would require Model 102-042400. (4 x 3 = 12) + 6 = 18 inputs.

Sizing tip - inputs needed

The number of inputs needed is equal to the number of impact valves less any impact valves used on diesel satellites.

Spreadsheet sizing programs

This program can be used to determine our model numbers.  Just enter the number of submersible pumps and dispensers and it will display the proper model number.

Click to download MS Excel Version of our Sizing Spreadsheet

 